REM-POD-EMT
(REV 2.0)
PROGRAMMABLE
REM-POD-EMT (REV 2.0) INCLUDES TEMPERATURE DEVIATION DETECTION AND REM
SENSITIVITY BOOST
User Instructions
Specification Difference REM-Pod-EMT (Rev 1.0) vs REM-Pod-EMT (Rev 2.0)
essentially all specifications are similar with the exception of the enhanced
sensitivity detection range on the new Rev 2.0 model. The new REM-Pod-EMT Rev
2.0 defaults to a sensitivity setting that when turned on, is equal to the
highest sensitivity setting of our previous REM-Pod-EMT Rev 1.0 model. The user
can then make an informed decision based on environmental conditions to elevate
the sensitivity four more steps which doubles the detection range of our
previous Rev 1.0 model. It is important to understand that this detection
sensitivity may need to be adjusted downward should you encounter external
interference. Interference will be noted by a random blinking green LED. The intent
of this extreme sensitivity modification is to try and amplify weaker
interactive energy and to also detect energy at a greater distance.
IMPORTANT INFORMATION TO NOTE:
-
Always be sure to
use a fresh 9VDC alkaline battery during your investigation. When a battery
needs to be changed, the REM-POD-EMT LEDs may start to fluctuate randomly. Be
sure to install the 9VDC battery correctly to prevent possible damage to the
circuit.
-
It is recommended
to remove the antenna (by unscrewing it at the base) before transportation as
to not incur damage to the antenna. Should the antenna become damaged at any
time, please contact support at 888-344-0111. The Antenna should be snug in
place however, slight movement is normal. If the antenna becomes loose, simply
tighten the antenna by screwing it into place at the base.
DIRECTIONS
FOR USE:
1. Remove the brown protective paper to expose the Red
Acrylic top.
2. The threaded screw antenna is located on the top of
the REM-POD-EMT. This may be snug but make sure it is always completely
tight. Gently extend the telescopic
antenna for REM use.
3. Located on the bottom of the REM-POD-EMT you will find
a slide switch that turns the REM function ON or OFF. In the REM setting, the
REM with EM field around the antenna will be activated.
4. The ATDD Power button located on the bottom of the Pod
allows for ± 1 to 5 degree Ambient Temperature Detection. PLEASE NOTE: To activate the Ambient Temperature Deviation
Detection (ATDD) circuit, the REM circuit must also be powered ON for the ATDD
circuit to function. Once activated, the ATDD will do a diagnostic check and
the circuit will baseline to the environment ambient temperature condition. The
temperature sensor is located on the top of the REM-POD-EMT adjacent to the
telescopic antenna. An LED on top of the Pod turns Red with ascending tones for
each + degree change and a Blue LED turns on with descending tones for a -
temperature change.
5. Once the REM-POD-EMT is turned ON, it goes through a
quick self-test diagnostic routine. You can adjust the REM detection sensitivity
level to suit your needs. The REM field and strength around the antenna is adjustable
using the momentary REM RANGE button on top of the Pod. Each time the button is
depressed, the detection range and sensitivity will increase by approximately
20%. When adjusting the sensitivity, the LEDs located on the top of the
REM-POD-EMT will blink to acknowledge the range setting. Press the momentary
switch to loop through the sensitivity range settings.
Sensitivity Level # 1 = Purple LED
Sensitivity Level # 2 = Purple & Red LEDs
Sensitivity Level # 3 = Purple, Red & Blue LEDs
Sensitivity Level # 4 = Purple, Red, Blue & Yellow
LEDs
Sensitivity Level # 5 = Purple, Red, Blue, Yellow
& Green LEDs
6. To test the REM-POD-EMT detection range, approach the
antenna (centered) from the left and right, using your left and right hands
simultaneously. The maximum detection distance for your hand is approximately ±
7 from the antenna for the new Rev 2.0 model vs. ± 3 from the antenna for the
Rev 1.0 model. Note: This detection distance can vary depending on
environmental conditions
7. The REM-POD-EMT has an Auto and Manual Baseline
Calibration adjustment. The REM Auto Baseline occurs approximately every seven
seconds. This is an important function because it will automatically adjust for
any interference from metal, fluorescent lights, and other conductive surfaces.
If you notice any interference from handheld communication devices like walkie
talkies, adjust the sensitivity level accordingly, or refrain from using them
during your investigation. Use the REM Zero button on top of the Pod to
baseline the REM feature if you need to. Also, if you are using more than one
Rem-Pod-EMT next to each other, be sure to separate them by at least 20.
8. The temperature circuit also has a Manual Baseline
adjustment. Make sure the REM-POD-EMT has at least ten minutes to adjust to the
surrounding Ambient Temperature prior to use. If the temperature in the room
rises or drops gradually and sticks on one degree (one tone), you can push the
ATDD ZERO button located on the top of the Pod to correct for this. Or, if the
sound remains on for more than ten seconds, the device will automatically mute
the sound until it senses the next ± 1 degree temperature change.